The most commonly used door closers?are external closers, which are installed in the following ways.
?
Here?is the content list:
l?Door closer installation methods
l?Door closer installation steps
?
Door closer installation methods
Door closers are generally divided into 3 types of installation
Option A - Regular Arm Installation
Option B - Top Jamb Installation
Option C-Parallel Arm Installation
?
Door closer installation steps
Due to the different ways of various installation methods, this is Option A - Regular Arm Installation:
1.Using the measurements from diagram ,mark screw hole center locations. Mark four(4)hole locations on door for door closer and two(2)hole locations on frame for arm shoe.
2.Drill pilot holes in door and frame, drill 7/32”(5.5mm)diameter holes for wood screws or drill and tap #7(.201”diameter)for 1/4-20 machine screws.
3.Install adjustable?forearm/arm shoe to frame using screws(c)or(d).
4.Mount closer on door using screws(a)or(b).SPEED ADJUSTING VALVES MUST BE POSITIONED TOWARDHINGE SIDE. 5.Install main arm to top pinion shaft, perpendicular to door. Secure tightly with arm screw/washer(e).
6.Adjust closing speed
7.Snap pinion cap over shaft at bottom of closer or install cover.
?
Specific installation methods, please refer to the specific models of each manual.
?